Overview

Selected Projects

A representative sample of Taut Engineering projects. Most clients come through Upwork or referral. Project locations span all fifty states and internationally.

Foundation

Pylon Sign Drilled Shaft Foundations

LPILE analysis with Reese weak-rock p-y model to justify reduced embedment into limestone. ACI 318 shear design with the size-effect provision. Stamped calculation package for permit.

Geotechnical / Foundation · KY

Canopy Foundation Design for Fueling Station

Spread footing design for canopy columns in variable soil conditions. Coordinated with geotechnical report for bearing capacity and settlement criteria.

Foundation · OH

Helical Pier Load Testing Evaluation

Independent review of helical pier load test data for a residential addition in expansive clay. Evaluated installation torque vs. capacity correlations and provided written opinion on adequacy.

Geotechnical · TX
Structural steel

Freestanding Scoreboard Structure

Site-specific adaptation of a manufacturer scoreboard structure to CBC wind and seismic loads. Drilled pier foundation design, Excel calculation package, and PE seal for permit.

Structural Steel · CA

Mezzanine Structural Adequacy Review

Structural review of an existing steel mezzanine for increased live load (warehouse to manufacturing). Checked beams, columns, and connections and documented deficiencies with remediation options.

Structural Steel · OH
Solar

Ballasted Rooftop PV Array, Commercial Building

ASCE 7 wind analysis and ballast calculation for a 250kW rooftop array on a flat membrane roof. Roof framing checked for concentrated ballast loads. PE-stamped letter report for AHJ.

Solar Racking · OH

Ground-Mount Solar Array, Agricultural Property

Structural review of ground-mount racking for a 50kW agricultural solar installation. Wind and snow load calculations, driven post foundation design, and PE stamp for utility interconnect.

Solar Racking · KY

Steel Solar Carport Structural Calculator

Built a parameterized Excel calculator for steel solar carport structures that generates ASCE 7 wind and snow loads and sizes the primary structural members across multiple regional wind and snow markets. Includes IBC code references throughout, a corrected Case B wind load factor, a ledger beam designed as a double-overhanging member, and a self-supporting-panel check that flags when the modules contribute structurally. Maintained in parallel market and configuration versions to support repeatable carport design across jurisdictions.

Solar / Structural · Various
Automation

SAP2000 Model Generator for Parametric Canopy Studies

Python tool to build and run SAP2000 models for canopy structures from a parameter file. Used to generate and post-process over 200 geometry variants for a manufacturer's design catalog.

Python / SAP2000 Automation
Plan review

Cold-Formed Steel Framing Review, Multi-Family Residential

Third-party structural review of CFS wall, floor, and roof framing for a 4-story wood and CFS hybrid building. Identified undersized jamb studs at large openings and an unbraced length error in a long-span floor joist.

Plan Review / CFS · CA

PE Stamping, Structural Steel Shop Drawings

Review and PE seal for structural steel connection shop drawings for multiple projects. Each review includes a written confirmation that the connections are adequate for the specified loads.

Plan Review / Structural · Various

Contact me about a project →